HALBH系列电缆护层保护器

产品详细描述
HALBH系(xi)列电缆护(hu)层保护(hu)器
流(liu)过高(gao)压(ya)单芯电(dian)(dian)(dian)缆(lan)的电(dian)(dian)(dian)流(liu)在(zai)铅包(bao)或金属屏蔽层(ceng)(ceng)产(chan)生感应(ying)(ying)(ying)电(dian)(dian)(dian)压(ya),当电(dian)(dian)(dian)缆(lan)线(xian)(xian)(xian)路较长时,感应(ying)(ying)(ying)过电(dian)(dian)(dian)压(ya)超出了(le)电(dian)(dian)(dian)缆(lan)护(hu)(hu)(hu)层(ceng)(ceng)绝缘(yuan)耐受电(dian)(dian)(dian)压(ya)值导致电(dian)(dian)(dian)缆(lan)护(hu)(hu)(hu)层(ceng)(ceng)绝缘(yuan)层(ceng)(ceng)被击穿。为此必须采(cai)取预防措(cuo)施(shi)来(lai)限(xian)制(zhi)(zhi)感应(ying)(ying)(ying)过电(dian)(dian)(dian)压(ya),其中较好的措(cuo)施(shi)是采(cai)用电(dian)(dian)(dian)缆(lan)护(hu)(hu)(hu)层(ceng)(ceng)保护(hu)(hu)(hu)器。电(dian)(dian)(dian)缆(lan)护(hu)(hu)(hu)层(ceng)(ceng)保护(hu)(hu)(hu)器用氧化(hua)锌非线(xian)(xian)(xian)性电(dian)(dian)(dian)阻片,外(wai)覆耐高(gao)温的硅橡(xiang)胶外(wai)套制(zhi)(zhi)成。它使用于一端(duan)接(jie)地的电(dian)(dian)(dian)缆(lan)线(xian)(xian)(xian)路的非接(jie)地端(duan)和交叉互联的电(dian)(dian)(dian)缆(lan)线(xian)(xian)(xian)路中的绝缘(yuan)接(jie)头处。
1、产品特(te)点
·优异的(de)保护特性(xing),有效限(xian)期感应过电压
·优良的电压——电流特性曲线,通流能力大,保护曲线平坦
· 硅橡胶外套采用整体一次成型工(gong)艺,密(mi)封性能好,安全防爆。
2、型(xing)号说明(ming)
HALBH-□/□
HALBH表示电缆护层保护器;
□/□分子表示标称放电电流下的残压(kV);分母表示2000μs方波通流容量(A)
3、主要技术指(zhi)标
电缆护层保(bao)护器主要技术(shu)参数(shu)
产品型号 |
适用 电缆系统 电压 |
额定电压(有效值) |
持续运行电压 (有效值) |
8/20μs标称放电电流 |
直流参考电压U1mA |
0.75 U1mA下的泄漏电流 |
标称放电电流下的残压 (峰值) |
2000μs方波电流(幅值) |
1.05Uc下的局部放电量 pC |
4/10μs大电流冲击耐受 (峰值) |
|
kV |
kV |
kV |
kA |
kV |
μA |
kV |
A |
kA |
|
HALBH-7/200 |
35 |
2.8 |
2.24 |
5 |
≥4.0 |
≤30 |
≤7 |
200 |
≤14 |
65 |
HALBH-7/400 |
110 |
2.8 |
2.24 |
10 |
≥4.0 |
≤30 |
≤7 |
400 |
≤14 |
100 |
HALBH-7/600 |
110 |
2.8 |
2.24 |
10 |
≥4.0 |
≤30 |
≤7 |
600 |
≤14 |
100 |
HALBH-10/400 |
110/220 |
3.6 |
2.64 |
10 |
≥5.8 |
≤30 |
≤10 |
400 |
≤14 |
100 |
HALBH-10/600 |
220 |
4.0 |
3.2 |
10 |
≥5.8 |
≤30 |
≤10 |
600 |
≤14 |
100 |
硅(gui)橡胶(jiao)外套(tao)理化性能
硬度 邵氏A度 |
撕裂强度 (kN/m) |
表面接触角 (°) |
击穿场强 (MV/m) |
体积电阻率 (Ω·cm) |
阻燃性 (级) |
耐漏电起痕 (级) |
52±2 |
≥25 |
106 |
≥25 |
8.6×1015 |
FH 1 |
1A4.5 |
4、验收、预试
验收:型号,数量与订货合同一致,外观无破损,合格证、生产日期、产品编号、U1mA数
据齐全;
预试:建议试验U1mA和0.75U1mA下的电流值,预试周期5年;禁止交流工放电压试验。
5、注意(yi)事项
·对母线进(jin)行耐(nai)压(ya)试(shi)验时,应脱开保护器;
·安装前应记录本产品出厂时的U1mA值,作为今后预试时的参考;
·预试时采用的直流电源谐波分量应尽量小,当试验电压波形不好时,U1mA值偏低。
6、产品示意图(tu)
产品型号 |
结构高度(mm) |
直径(mm) |
伞径(mm) |
图号 |
备 注 |
HALBH-7/200 |
120 |
67 |
108 |
图1 |
丝标(biao)长度 可根据用(yong) 户要求配 置。 |
120 |
67 |
76 |
图2 |
||
HALBH-7/400 |
120 |
67 |
108 |
图(tu)1 |
|
120 |
67 |
76 |
图(tu)2 |
||
HALBH-7/600 |
130 |
76 |
96 |
图3 |
|
HALBH-10/400 |
130 |
76 |
96 |
图3 |
|
HALBH-10/600 |
130 |
76 |
96 |
图3 |